OFFER FORM

You can send us your suggestions, complaints and requests for products via the form below.

    CAPACITY CALCULATION

    With our capacity calculation application, you can calculate your heat capacity in accordance with the values you have entered.

    BUILDING AREA (M²)
    CEILING HEIGHT (MT)
    BUILDING LOCATION
    BUILDING LOCATION

    *The heat capacities calculated according to the values you have entered are given as completely estimated information and Kozlusan does not guarantee the accuracy of these values at any time.

    *For the most accurate information, please contact one of our nearest authorized dealers or installation engineering companies.

    Thermokoz | Trump (Ash Sticker)
    Aqueous System

    Trump (Ash Sticker)

    KOZ Series is a powerful heating solution with highly efficient, automated systems for industrial and commercial areas.

    While offering easy operation with its advanced automation features, it offers a long-lasting and economical heating system with its durable structure.

    Experience a more efficient, more economical and more comfortable heating experience with Kozlusan KOZ Series!

    Color Option

    Thermokoz | Trump (Ash Sticker) Red

    Our product provides economy
    with its highly efficient body design and
    turbulators in smoke pipes. It offers comfort to the user with its rich
    functions such as automatic loading, ash removal,
    automatic mixing system etc.

    Whatsapp Support

    General Features

    Technical Specifications

    Documents

    Images & Videos

    Thermokoz | Trump (Ash Sticker)
    It offers ‘Automatic Fuel Loading’ by rotating the auger with the help of the electronic fuel supply motor. In this way, you can warm up without getting up from your place and with balanced fuel consumption.

    Automatic Fuel Loading

    Thermokoz | Trump (Ash Sticker)
    Where does the waste from all these cleaned areas go? The answer to this is given by the "Automatic Ash Removal" system... We transfer the cleaned ash and pellet residues to the ash box located outside the device. In this way, you can empty the ash box in a more sterilized and hygienic way at regular intervals.

    Automatic Ignition

    Thermokoz | Trump (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. The device will automatically load the fuel level in line with the temperature value you set, and then automatically ignite the ignition within a short period of 5 minutes to make it work.

    Automatic Ash Extraction

    Thermokoz | Trump (Ash Sticker)
    The slag layer that forms on the top of the coal causes the flame to weaken and unburned coal to be wasted. However, our Automatic Stirring Furnace eliminates this problem, ensuring 100% efficient combustion . Thanks to its innovative design, it always delivers a strong and effective heat , minimizing energy losses. Be one step ahead now for high efficiency, maximum performance!

    Automatic Mixing

    Thermokoz | Trump (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! This smart system, which meets your hot water needs in every season throughout the year, makes your life easier with its energy efficiency and superior performance. Always enjoy hot water , do not compromise on your comfort!

    Boiler Integration

    Thermokoz | Trump (Ash Sticker)
    Thanks to Sleep Mode, your boiler is automatically ignited and activated at specific time periods to keep the fire alive during long standby periods. This innovative feature offers uninterrupted comfort and maximum energy savings. Your heat is always at the ideal level, your energy efficiency is at the highest level!

    Sleep Mode

    Thermokoz | Trump (Ash Sticker)
    It offers ‘Automatic Fuel Loading’ by rotating the auger with the help of the electronic fuel supply motor. In this way, you can warm up without getting up from your place and with balanced fuel consumption.

    Automatic Fuel Loading

    Thermokoz | Trump (Ash Sticker)
    Where does the waste from all these cleaned areas go? The answer to this is given by the "Automatic Ash Removal" system... We transfer the cleaned ash and pellet residues to the ash box located outside the device. In this way, you can empty the ash box in a more sterilized and hygienic way at regular intervals.

    Automatic Ignition

    Thermokoz | Trump (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. The device will automatically load the fuel level in line with the temperature value you set, and then automatically ignite the ignition within a short period of 5 minutes to make it work.

    Automatic Ash Extraction

    Thermokoz | Trump (Ash Sticker)
    The slag layer that forms on the top of the coal causes the flame to weaken and unburned coal to be wasted. However, our Automatic Stirring Furnace eliminates this problem, ensuring 100% efficient combustion . Thanks to its innovative design, it always delivers a strong and effective heat , minimizing energy losses. Be one step ahead now for high efficiency, maximum performance!

    Automatic Mixing

    Thermokoz | Trump (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! This smart system, which meets your hot water needs in every season throughout the year, makes your life easier with its energy efficiency and superior performance. Always enjoy hot water , do not compromise on your comfort!

    Boiler Integration

    Thermokoz | Trump (Ash Sticker)
    Thanks to Sleep Mode, your boiler is automatically ignited and activated at specific time periods to keep the fire alive during long standby periods. This innovative feature offers uninterrupted comfort and maximum energy savings. Your heat is always at the ideal level, your energy efficiency is at the highest level!

    Sleep Mode

    Thermokoz | Trump (Ash Sticker)
    It offers ‘Automatic Fuel Loading’ by rotating the auger with the help of the electronic fuel supply motor. In this way, you can warm up without getting up from your place and with balanced fuel consumption.

    Automatic Fuel Loading

    Thermokoz | Trump (Ash Sticker)
    Where does the waste from all these cleaned areas go? The answer to this is given by the "Automatic Ash Removal" system... We transfer the cleaned ash and pellet residues to the ash box located outside the device. In this way, you can empty the ash box in a more sterilized and hygienic way at regular intervals.

    Automatic Ignition

    Thermokoz | Trump (Ash Sticker)
    Of course, you do not need to ignite the loaded fuel with your hand. The device will automatically load the fuel level in line with the temperature value you set, and then automatically ignite the ignition within a short period of 5 minutes to make it work.

    Automatic Ash Extraction

    Thermokoz | Trump (Ash Sticker)
    The slag layer that forms on the top of the coal causes the flame to weaken and unburned coal to be wasted. However, our Automatic Stirring Furnace eliminates this problem, ensuring 100% efficient combustion . Thanks to its innovative design, it always delivers a strong and effective heat , minimizing energy losses. Be one step ahead now for high efficiency, maximum performance!

    Automatic Mixing

    Thermokoz | Trump (Ash Sticker)
    With the boiler sensor and boiler pump start-up feature, your boiler is now guaranteed to produce hot water in summer and winter! This smart system, which meets your hot water needs in every season throughout the year, makes your life easier with its energy efficiency and superior performance. Always enjoy hot water , do not compromise on your comfort!

    Boiler Integration

    Thermokoz | Trump (Ash Sticker)
    Thanks to Sleep Mode, your boiler is automatically ignited and activated at specific time periods to keep the fire alive during long standby periods. This innovative feature offers uninterrupted comfort and maximum energy savings. Your heat is always at the ideal level, your energy efficiency is at the highest level!

    Sleep Mode

    Thermokoz | Trump (Ash Sticker)
    MODEL
    Capacity kW 150
    Width (A) mm 1850
    Length (B) mm 2000
    Height (C) mm 1600
    Cold Water Inlet Height (D) mm 530
    Hot Water Outlet Height (E) mm 1600
    Flue Outlet Height (F) mm 1260
    Flue Diameter mm 250
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1/2
    Weight kg 960
    Water Capacity lt 350
    Tank Capacity lt 230
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 180
    Fan Power W 240
    Ash Box Capacity l 50
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 175
    Width (A) mm 2050
    Length (B) mm 2100
    Height (C) mm 1900
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1900
    Flue Outlet Height (F) mm 1300
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1540
    Water Capacity lt 470
    Tank Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 209
    Width (A) mm 2050
    Length (B) mm 2100
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1600
    Water Capacity lt 520
    Tank Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 232
    Width (A) mm 2050
    Length (B) mm 2200
    Height (C) mm 2000
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 2000
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1715
    Water Capacity lt 585
    Tank Capacity lt 450
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 290
    Width (A) mm 2400
    Length (B) mm 2300
    Height (C) mm 2200
    Cold Water Inlet Height (D) mm 650
    Hot Water Outlet Height (E) mm 2200
    Flue Outlet Height (F) mm 1600
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 2080
    Water Capacity lt 1050
    Tank Capacity lt 600
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 348
    Width (A) mm 2400
    Length (B) mm 2850
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1750
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 3490
    Water Capacity lt 1350
    Tank Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 465
    Width (A) mm 2500
    Length (B) mm 3250
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1900
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 3500
    Water Capacity lt 1700
    Tank Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 581
    Width (A) mm 2800
    Length (B) mm 3550
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 4000
    Water Capacity lt 2500
    Tank Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 697
    Width (A) mm 2750
    Length (B) mm 3550
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 5550
    Water Capacity lt 3380
    Tank Capacity lt 600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 814
    Width (A) mm 3400
    Length (B) mm 4050
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 790
    Hot Water Outlet Height (E) mm 2800
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 6000
    Water Capacity lt 4260
    Tank Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 930
    Width (A) mm 3400
    Length (B) mm 4250
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 790
    Hot Water Outlet Height (E) mm 2800
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 6770
    Water Capacity lt 4670
    Tank Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 1100
    Fan Power W 2×550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 24
    Capacity kW 1160
    Width (A) mm 3400
    Length (B) mm 4500
    Height (C) mm 3000
    Cold Water Inlet Height (D) mm 800
    Hot Water Outlet Height (E) mm 3000
    Flue Outlet Height (F) mm 2350
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 7500
    Water Capacity lt 4800
    Tank Capacity lt 1600
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Reducer Power W 750
    Fan Power W 2×550
    Ash Box Capacity l 95
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 24
    Thermokoz | Trump (Ash Sticker) PDF
    User Guide
    Thermokoz | Trump (Ash Sticker) PDF
    Maintenance and Service Manual
    Thermokoz | Trump (Ash Sticker) PDF
    Assembly and Delivery Guide
    Thermokoz | Trump (Ash Sticker) PDF
    Technical Drawing