OFFER FORM

You can send us your suggestions, complaints and requests for products via the form below.

    CAPACITY CALCULATION

    With our capacity calculation application, you can calculate your heat capacity in accordance with the values you have entered.

    BUILDING AREA (M²)
    CEILING HEIGHT (MT)
    BUILDING LOCATION
    BUILDING LOCATION

    *The heat capacities calculated according to the values you have entered are given as completely estimated information and Kozlusan does not guarantee the accuracy of these values at any time.

    *For the most accurate information, please contact one of our nearest authorized dealers or installation engineering companies.

    Thermokoz | Koz X
    Aqueous System

    Koz X

    Millionaire KOZ-X Series offers a flexible and efficient heating solution with its ability to burn coal and wood.

    While optimizing fuel consumption thanks to its highly efficient combustion system, its robust and durable structure ensures long-lasting use.

    It is an economical and safe heating option with its digital control panel and environmentally friendly design.

    Color Option

    Thermokoz | Koz X Red

    Our product provides economy
    with its highly efficient housing design and
    .

    Whatsapp Support

    General Features

    Technical Specifications

    Documents

    Images & Videos

    Thermokoz | Koz X
    Thanks to the ability of the boiler to burn coal and wood, you can choose your fuel according to your needs. It offers both an economical and environmentally friendly heating solution. The combustion chamber compatible with different fuel types offers ease of use while providing high efficient heating.

    Coal and Wood Burning

    Thermokoz | Koz X
    Thanks to the ability of the boiler to burn coal and wood, you can choose your fuel according to your needs. It offers both an economical and environmentally friendly heating solution. The combustion chamber compatible with different fuel types offers ease of use while providing high efficient heating.

    Coal and Wood Burning

    Thermokoz | Koz X
    Thanks to the ability of the boiler to burn coal and wood, you can choose your fuel according to your needs. It offers both an economical and environmentally friendly heating solution. The combustion chamber compatible with different fuel types offers ease of use while providing high efficient heating.

    Coal and Wood Burning

    Thermokoz | Koz X
    MODEL
    Capacity kW 150
    Width (A) mm 920
    Length (B) mm 2000
    Height (C) mm 1600
    Cold Water Inlet Height (D) mm 530
    Hot Water Outlet Height (E) mm 1600
    Flue Outlet Height (F) mm 1260
    Flue Diameter mm 250
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1/2
    Weight kg 750
    Water Capacity lt 350
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 240
    Operating Voltage and Frequency V/Hz 230/50
    Operating Current A 16
    Capacity kW 174
    Width (A) mm 1150
    Length (B) mm 2100
    Height (C) mm 1750
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1750
    Flue Outlet Height (F) mm 1300
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1150
    Water Capacity lt 470
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 16
    Capacity kW 209
    Width (A) mm 1150
    Length (B) mm 2100
    Height (C) mm 1850
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1850
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1300
    Water Capacity lt 520
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 16
    Capacity kW 232
    Width (A) mm 1150
    Length (B) mm 2250
    Height (C) mm 1850
    Cold Water Inlet Height (D) mm 500
    Hot Water Outlet Height (E) mm 1850
    Flue Outlet Height (F) mm 1400
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1450
    Water Capacity lt 585
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 16
    Capacity kW 290
    Width (A) mm 1500
    Length (B) mm 2300
    Height (C) mm 1950
    Cold Water Inlet Height (D) mm 650
    Hot Water Outlet Height (E) mm 2050
    Flue Outlet Height (F) mm 1600
    Flue Diameter mm 300
    Flow – Return inch 2 1/2
    Expansion Outlet inch 1 1/2
    Fill – Drain inch 1
    Weight kg 1716
    Water Capacity lt 1050
    Max. Operating Pressure bar 3
    Test Pressure bar 4.3
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 16
    Capacity kW 348
    Width (A) mm 1600
    Length (B) mm 2850
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1750
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 2850
    Water Capacity lt 1350
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 465
    Width (A) mm 1600
    Length (B) mm 3250
    Height (C) mm 2250
    Cold Water Inlet Height (D) mm 720
    Hot Water Outlet Height (E) mm 2250
    Flue Outlet Height (F) mm 1750
    Flue Diameter mm 400
    Flow – Return inch 3
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 3450
    Water Capacity lt 1750
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 581
    Width (A) mm 1850
    Length (B) mm 3550
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 4150
    Water Capacity lt 2500
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 697
    Width (A) mm 1850
    Length (B) mm 4000
    Height (C) mm 2550
    Cold Water Inlet Height (D) mm 730
    Hot Water Outlet Height (E) mm 2550
    Flue Outlet Height (F) mm 1950
    Flue Diameter mm 500
    Flow – Return inch 4
    Expansion Outlet inch 2
    Fill – Drain inch 2
    Weight kg 4610
    Water Capacity lt 3190
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 814
    Width (A) mm 2050
    Length (B) mm 4000
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2800
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 5100
    Water Capacity lt 3500
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 930
    Width (A) mm 2050
    Length (B) mm 4250
    Height (C) mm 2800
    Cold Water Inlet Height (D) mm 750
    Hot Water Outlet Height (E) mm 2800
    Flue Outlet Height (F) mm 2250
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 5500
    Water Capacity lt 3900
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18
    Capacity kW 1160
    Width (A) mm 2150
    Length (B) mm 4500
    Height (C) mm 3000
    Cold Water Inlet Height (D) mm 800
    Hot Water Outlet Height (E) mm 3000
    Flue Outlet Height (F) mm 2350
    Flue Diameter mm 600
    Flow – Return inch 5
    Expansion Outlet inch 2 1/2
    Fill – Drain inch 2 1/2
    Weight kg 6000
    Water Capacity lt 4800
    Max. Operating Pressure bar 5
    Test Pressure bar 7.15
    Temperature Control Range °C 45-85
    Max. Operating Temperature °C 90
    Fan Power W 2×550
    Operating Voltage and Frequency V/Hz 380/50
    Operating Current A 18